| Specifications |
950FX
(medium temp) |
| Flux Capacity |
600 lbs (272 Kg) granulated
flux |
| Heating Element |
3.0 KW (tubular type) |
| Voltage |
240V or 480V (specify one)
50 or 60 cycles, AC, three phase |
| Input Connection |
Terminal block for field
wiring |
| Temperature Range |
100° to 450° F (39° to 232°
C) |
| Thermostat |
Adjustable control with
indicator light,
100° to 450° F (38° to 232°C) +/- 25°F |
| Insulation |
2" (5cm) Glass Fiber Batt |
| Chamber |
6 1/2 cu. ft. (.18m3),
hopper type |
| Loading Method |
Removable insulated top cover
- load by hand |
| Discharge |
Sloping Bottom - Gravity flow
thru, 3" (7.6cm) Dia. opening with dispensing valve |
| Exterior Dimensions
Net Weight
|
39-1/2" Dia. x 35"H
(100.3 x 88.9 cm)
325 lbs (147 Kg)
|
| Shipping Dimensions
Shipping Weight
|
43" x 43" x 45" (109.2.2 x 109.2 x
114.3cm)
approx 375 lbs (170 Kg)
|